PCU Product Brochure
Rev B · October 2026
Molitron Pollution Control Unit (PCU) · Models EPFA-24 to EPFA-144
Filter smoke and grease before they leave your kitchen.
A UL Listed stainless-steel filter unit that installs in your kitchen exhaust duct, between the hood and the fan. Three dry filter stages capture smoke particulate and grease vapor, with no water, pumps or chemicals.

EPFA-84 shown, rendered from Molitron’s 3D model of the unit
- 3dry filter stages
- 1,800–10,800CFM across 11 models
- Type 304stainless steel, fully welded
- UL 8782Listed, File MH45752
01
Three stages, one direction.
Exhaust from the hood enters the PCU and passes through three banks of filters in turn, pre-filters first, before it reaches the fan.

F1 Pre-filter
Multi-pocket pre-filters are the first bank the exhaust meets, catching the larger particles and grease.
F2 High-efficiency filter
Multi-pocket high-efficiency filters capture the fine smoke particulate and grease vapor that pass the pre-filter.
F3 Final stage
A second high-efficiency bank, or optional carbon filters when odor treatment is part of the project. Carbon replaces F3; it does not add a fourth stage.

Odor treatment option
Carbon filters in the final stage
Where odor treatment is part of the project, carbon filters take the place of the F3 bank. Standard filtration is not comprehensive odor treatment; for broader odor control, Molitron’s MOAS can be evaluated with the PCU.
02
Find your model.
Eleven models, EPFA-24 through EPFA-144, share one 63-inch length. Width sets the airflow: choose the model whose planning airflow covers your exhaust.
| Model | Planning airflow, CFM | Width | Approx. weight | Carbon adds |
|---|---|---|---|---|
| EPFA-24 | 1,800 | 24 in. | 250 lb | 72 lb |
| EPFA-36 | 2,700 | 36 in. | 350 lb | 108 lb |
| EPFA-48 | 3,600 | 48 in. | 450 lb | 144 lb |
| EPFA-60 | 4,500 | 60 in. | 550 lb | 180 lb |
| EPFA-72 | 5,400 | 72 in. | 650 lb | 216 lb |
| EPFA-84 | 6,300 | 84 in. | 750 lb | 252 lb |
| EPFA-96 | 7,200 | 96 in. | 850 lb | 288 lb |
| EPFA-108 | 8,100 | 108 in. | 950 lb | 324 lb |
| EPFA-120 | 9,000 | 120 in. | 1,050 lb | 360 lb |
| EPFA-132 | 9,900 | 132 in. | 1,150 lb | 396 lb |
| EPFA-144 | 10,800 | 144 in. | 1,250 lb | 432 lb |

03
Indoors or on the roof.
- In the exhaust path
- Anywhere between the kitchen hood and the exhaust fan, with the inlet from the kitchen and the outlet toward the fan.
- Indoors or on the roof
- Hung from the hanger angles at each top corner, or set on a code-approved roof curb by the installing contractor.
- Footprint
- Model width × 63 in. long. Every model shares the 63-inch length.
- Service side
- 30 in. of free space in front of the access doors.
- Other sides
- 18 in. to combustible materials and building insulation, or zero clearance to noncombustible materials.
- Above a ceiling
- A permanent service platform, level with the bottom of the unit, is required.
04
Easy to live with.
A status panel in your kitchen or office tells your staff when the filters need attention.
- Every four weeks, inspect and service the filters.
- Blinking red means service now, whatever the date.
- Replacement filters come from Molitron, matched to the originals.
- Cleaning is a steam clean of the stainless interior.



05
Built and listed.
- Enclosure
- 18-gauge Type 304 stainless steel, fully welded.
- Access
- Three removable, gasketed stainless access doors. Doors on both sides are optional.
- Fire protection
- Fire-suppression pre-piping from Molitron, ready for ANSUL or another brand you select.
- Drains
- Three cleaning drains, piped by others to the grease interceptor.
- Monitoring
- A wall-mounted status panel comes standard. The unit’s controls take a 120 VAC supply, by others.
UL Listed. Models EPFA-24 through EPFA-144 are UL Listed under File MH45752, investigated to UL 8782, the Outline of Investigation for Pollution Control Units for Commercial Cooking Operations.